imagehomecontactproductsheader

Eaziflo dust / fume collector

 

Eaziflo

EazifloThe Welding Manufacturer's Association of Australia recommends that the level of welding fume in the welder's breathing zone should be less than 5mg per cubic metre.
90% filtration efficiency to 0.5 micron size, combined with effective ventilation, will result in concentrations well below 5mg per cubic metre. 

Welding fumes comprise: 

mostly residual dust associated with metal burning and electrode burning, typically in the 0.5 micron to 1.0 micron range.

a smaller proportion oxides in the 0.01 to 1.0 micron range but mainly toward the 1.0 micron end. 

The respiratory standard AS1715-91 states that every effort should be made to prevent the release of airborne particles into the working environment.
"At source" extraction is the preferred method of control.

The Eaziflo's secret is its all-Australian designed "high efficiency filter system". This means extraction rates as high as 80%. 

Eaziflo exceeds standard 
All Eaziflo filtration systems exceed the standard for removing weld fume dust from welding bays which recommends a 90% efficiency filter to 0.5 micron,
achieving 5mg per cubic metreof welding fume in the welder's breathing zone. 

Eaziflo minimises running costs 
The low cost but high efficiency Clyde Inter-fold prefilter should always be used to maximise the life of the Clyde Inter-firm filter.
Check the Clyde Interfold pre-filter regularly and de-dust by tapping where practical and safe. We recommend that the filter be disposed of when dirty. 

Eaziflo removes gas/odour 
Gaseous contaminant will be present during some welding operations. The Clyde Interflow80D charcoal filter will fit the Eaziflo systems and remove odours and fume.
The air flow is reduced to 354 L/S from the total standard air flow of 708 L/S. This is to allow the gases a slow path through the charcoal absorber to ensure removal of the contaminant from the air stream. 

Eaziflo is safe and economical for every welding applicationEaziflo offers filtration efficiencies of: 

60-65% on 1.0 micron - Clyde Inter-firm 65 Rigid Pleated Filters

80-85% on 1.0 micron - Clyde Inter-firm 85 Rigid Pleated Filters

90-95% on 0.5 micron - Clyde Inter-firm 95 Rigid Pleated Filters

About the filtration used in the Eaziflo equipment - 

Clyde-Apac Inter-firm 65% Rigid Pleated Filters: The Inter-firm is standard with all Eaziflo systems and is protected by a Clyde Inter-fold prefilter and spark arrestor offering 3-stage filtration.

Clyde-Apac Inter-firm 85% Rigid Pleated Filters: When using heavy fume welding consumables, e.g.hard facing wire, the Inter-firm is suited to capture greater quantities of coarse dust and provide longer filter service life.

Clyde-Apac Inter-firm 95% Rigid Pleated Filters: The Inter-firm would be recommended when hazardous fume is present, e.g. silica, barium, asbestos.



On - Gun System Eaziflo 93784

On - Gun System Eaziflo 
Light & Medium Duty Unit.

This lightweight, heavy duty 'on-gun' Eaziflo removes weld smoke, fume and particulates directly from the arc source. It provides maximum safety for the operator and the environment. It exhausts through a two or three stage optional charcoal filter. 

The Eaziflo on-gun system is the first all Australian fume extractor built for use with the on-gun mig and tig welding systems. 
Every welding operation should be smoke-free. The energy saving on-gun direct control is a unique design feature which also assists occupational health by providing noise reduction in the factory environment. The deep filter compartment takes three stages of maxi-pack filtration, offering twice the filtering capacity and service life of competitor systems. The fast changeout standard Clyde Inter-firm filter pack means very little down time for service and operator lost time. 

Note: For heavy duty welding applications please order 
on-gun model 93784(H).

An adjustable 'over-run' facility ensures the removal of al residual after-fume. Filter performance is monitored by the 0-500 Pa filter loss gauge. 

Technical Specifications (for light and medium duty use)

Dimension: 655 x 330 x 490 mm 
Net Weight: 35 kg
Air Flow Volume: 1 motor 24L/S (50.7 cfm)
Motor Input: 240 Volt 50Hz
Motor Size:

1050 watt

Motor Speed: 14,000 rpm
Primary Filter Part Number: PF CV25-305610
Secondary Filter Part Number: IFC Interfirm P.A. FR85-305610152
Charcoal Adsorber: IFC Chemasorb 80(D)
Spark Arrestor Filter: PUH AUHB 888888

Due to ongoing research & development, Clyde-Apac reserves the right to modify the product & specifications without notice.